Üzümcü Medical Systems

EK-410 PRODUCT DETAIL

EK-410
Electrosurgical Unit

Description

UZUMCU Electro Surgical Units are used for all dry and wet surgical operations in safety. They are available different cut and coagulation current. They operate with high frequency.

Product Name:

Electrosurgical Unit

Description

UZUMCU Electro Surgical Units are used for all dry and wet surgical operations in safety. They are available different cut and coagulation current. They operate with high frequency.

Technical properties

EK-410 High frequency electrosurgical unit can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability.

 

TWIN OPERATION

• Two output channels for monopolar cutting

• Two independent setting and output channels for the most frequent monopolar coagulation

 

CONTROLLED CUTTING PROCEDURES

• Enhanced cutting current for eschar free incision

• Cutting current with selectable coagulating property for bleeding controlled dissection

• Low capacitive coupling by slow BLEND current for endoscopic procedures

 

TWIN CONTROLLED COAGULATIVE PROCEDURES

• SPEEDY (Fulgurate / Forced) coagulation and DEEP (Pin Point / Dessicate / Soft) coagulation available to two operators

• SPRAY coagulation available by hand switch or foot switch controls

 

WIDE BIPOLAR FEATURES

• Bipolar cutting current with selectable bleeding control

• Slow BLEND cutting current

• Separately activable Automatic Start/Stop coagulation

 

SURGEON AND PATIENT SAFETY

• Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)

• H.F. Leakage currents continuously monitored

• Mains fluctuation automatically compensated before to start the delivery of HF power

 

PERSONALIZED PROCEDURES

• Independent choise of coagulative currents and power levels by each of two operators

• Ten personal configurable and immediately recallable procedures

 

EXTENTION DRIVER AND INTERLOCK SIGNALS

• Drived output connection to external Argon Plasma unit and Smoke Evacuator unit

 

AUTOMATIC SELF DIAGNOSIS

• Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures

 

CONTROLS

Patient / Plate circuit monitoring

Output power monitoring

Self check control

H.F. Leakage currents control

Compensation of mains fluctuation

 

Specifications:

Maximum output power monopolar pure CUT

400 W → 300 Ω

Maximum output power monopolar cut-coag CUT80%

300 W → 300 Ω

Maximum output power monopolar cut-coag CUT60%

250 W → 300 Ω

Maximum output power monopolar cut-coag CUT40%

200 W → 300 Ω

Maximum output power monopolar cut ENHANCED

250 W → 500 Ω

Maximum output power monopolar cut-coag BLEND

250 W → 300 Ω

Maximum output power monopolar coag SPEEDY

120 W → 500 Ω

Maximum output power monopolar coag DEEP

120 W  → 200 Ω

Maximum output power monopolar coag SPRAY

100 W → 2000 Ω

Maximum output power monopolar coag SPRAY ARGON

100 W → 2000 Ω

Bipolar

 

Maximum output power bipolar CUT

120 W → 150 Ω

Maximum output power bipolar cut-coag CUT80%

100 W → 150 Ω

Maximum output power bipolar cut-coag CUT60%

100 W → 150 Ω

Maximum output power bipolar cut-coag CUT40%

60 W → 150 Ω

Maximum output power bipolar cut-coag BLEND

100 W → 150 Ω

Maximum output power bipolar coag COAG

70 W → 100 Ω

Working frequency Monopolar / Bipolar

425 kHz / 525 kHz

Selectable input voltage

115- 230 Vac50 - 60 Hz

Electrical input power

1000 VA

Weight

178 kgs

Dimensions

470x380x150 mm

 

 

Written Documents

There isn't any document for the product.